Share

Related Links

Related Stories

  • Analyser measures suspended solids
    Liquid analysis specialist Electro-Chemical Devices (ECD), based in California, USA, has developed an analyser for the measurement of suspended solids in wastewater.
  • WEFTEC 2010
    Ranked in the top 1% of all trade shows in North America, and the largest annual water quality exhibition in the world, this year's WEFTEC will be held on 2–6 October 2010 in New Orleans, Louisiana, USA. Filtration + Separation canvassed some exhibitors to find out what would be on display.
  • Ground water: Dealing with iron contamination
    Iron contamination can present a number of problems for water filtration systems for agricultural, industrial and municipal applications. Daniel Ityel of Amiad Filtration Systems outlines the problems and introduces a new method of micro-fibre filtration after oxidation.
  • Oil and gas: Water treatment in oil and gas production – does it matter?
    Water is not normally associated in many people's minds with the production of oil and gas from underground reservoirs. Consequently, with no energy potential or sales value, is its separation, treatment and disposal important? David Robinson discusses issues surrounding the handling of water in the production of oil and gas.
  • Managing wastewater: Using membrane bioreactors for water supply
    In the quest for efficient and economical water use and land footprint in water production, membrane bioreactors (MBR) have been leading the way. In this article, we look at how the membranes in an MBR work, and some recent developments in this sector of the water industry.

Top 5 Stories

News

Electro-Chemical Devices releases Triton DO8 dissolved oxygen analyzer system

28 June 2010

The monitoring system solution for water treatment combines a multi-channel digital controller with a fluorescence quenching (FQ) sensing element.

Electro-Chemical Devices’ C22 multi-channel controller/monitor integrated with the Triton DO8 sensor creates a highly accurate oxygen analysis system. The C22 features a multi-bus architecture which allows up to four sensor inputs, six outputs and six relays. The Triton DO8 Sensor features a maximum error rate of less than 2%, repeatability of ±0.5% and resolution of 0.01 ppm or 0.01% saturation. The sensor operates over a wide measurement range with three different outputs from 0 to 20 mg/l (0-20 ppm), 0-200% saturation or 0-500 hPa (0-6 psi).

The Triton DO8 sensor can withstand ambient temperatures from -20 to 60°C (0-140°F) and records measurements at temperatures from -5 to 50°C (20-120°F). It withstands pressures up to a maximum of 10 bar (145 psi). A proven fluorescence quenching method enables the Triton DO8 sensor to determine the oxygen concentration in water. A circular layer of optically-active, oxygen-sensitive molecules is integrated into an easily replaceable cap. This durable layer is highly permeable to oxygen and rapidly equilibrates to its surroundings. The cap aligns the optically-active fluorescence layer above two optical components inside the sensor, an emitter and a detector.

After the sensor’s emitter flashes a green light at the layer, the layer fluoresces back a red light. The duration and intensity of the fluorescence are directly dependent on the amount of oxygen in the layer. With little to no oxygen in the layer, the response is longer and more intense. The presence of more oxygen, however, quenches (reduces) the fluorescence effect.

The Triton DO8 sensor calculates dissolved oxygen values by continuously analyzing the oxygen level, water temperature and air pressure. Via digital communications, the DO8 sends DO data to ECD’s C-22 Controller, which provides a 4-20 mA output signal to a water treatment plant’s control room. The RS-485 digital signal is nearly immune to common EMI/RFI noise that is typically a problem in many plant environments.


 

 

This article is featured in:
Cleaning & Purification  •  Wastewater & Sewage Treatment

 